AQA A-Level› Required Practicals› RP9: pH Titration Curves

RP9Required practical · Year 2 (A-level)

RP9: Weak/Strong Acids and Bases pH Titration Curves

Investigating how pH changes during neutralization and determining acid dissociation constants.

During an acid-base neutralization, the pH change is non-linear. By tracking pH continuously as base is added, we obtain a pH titration curve. This guide explores the differences between strong and weak acid titration curves, indicator selection, and calculating the acid dissociation constant (\(K_{\text{a}}\)).

Core Specification Link

This practical supports 3.1.12 Acids and bases, focusing on pH curves, titration calculations, indicators, buffer action, and \(K_{\text{a}}\) determination.

Apparatus Setup

To record titration curves, a pH electrode is submerged in an acid solution on a magnetic stirrer while a base is added incrementally from a burette:

pH Titration Setup 1.00 Burette with NaOH(aq) pH Meter pH Probe

Aim

To investigate how pH changes when (a) a strong acid reacts with a strong base, (b) a weak acid reacts with a strong base, and (c) a strong acid reacts with a weak base (specifically HCl + NH₃), and to select suitable indicators based on the resulting pH titration curves.

Equipment List

Experimental Method

Calibration of the pH Electrode

A pH meter measures the potential difference across a glass membrane. This potential shifts over time (electrode drift). To ensure accurate measurements, the meter must be calibrated using standard buffer solutions:

  1. Rinse the pH electrode thoroughly with distilled water and gently blot it dry.
  2. Submerge the electrode in the pH 7.00 buffer . Adjust the meter reading to read exactly 7.00.
  3. Rinse the electrode again and place it in the pH 4.00 buffer (or pH 10.00 buffer) . Adjust the scale calibration to match.

pH Measurements

  1. Pipette 25.0 cm³ of 0.10 mol dm⁻³ hydrochloric acid into a 250 cm³ beaker . Place the beaker on the magnetic stirrer, add the stirrer bar, and turn on the stirrer at a slow, steady speed.
  2. Position the pH electrode in the beaker so the bulb is fully submerged but clear of the rotating magnetic stirrer bar . Record the initial pH (at 0.0 cm³ base added).
  3. Fill the burette with 0.10 mol dm⁻³ sodium hydroxide solution.
  4. Add the sodium hydroxide in 1.0 cm³ portions . Record the volume added and the stable pH reading after each addition.
  5. Near the equivalence point (when pH begins changing rapidly, around pH 3 to 11): Reduce the addition increments to 0.20 cm³ to define the steep section of the curve.
  6. After passing the equivalence point and once the pH changes slow down again (above pH 11), return to 1.0 cm³ increments until a total of 40 cm³ of base has been added.
  7. Repeat steps 1 to 6 using 25.0 cm³ of 0.10 mol dm⁻³ ethanoic acid instead of hydrochloric acid (weak acid / strong base).
  8. Repeat the titration for a strong acid / weak base combination by titrating 25.0 cm³ of 0.10 mol dm⁻³ hydrochloric acid with 0.10 mol dm⁻³ aqueous ammonia in the burette.

Analysing pH Titration Curves

Titration Curves Comparison Phenolphthalein range (pH 8.2–10.0) Methyl orange range (pH 3.1–4.4) pH Volume of base added / cm³ 0 7 14 0 25 HCl + NaOH (strong acid, strong base) CH₃COOH + NaOH (weak acid, strong base) HCl + NH₃ (strong acid, weak base) Equivalence pH = 7 Equivalence pH = 8.8 Equivalence pH = 5.3 pH = pKa

1. Strong Acid + Strong Base (HCl + NaOH)

2. Weak Acid + Strong Base (CH₃COOH + NaOH)

3. Strong Acid + Weak Base (HCl + NH₃)

Worked Example: Determining \(K_{\text{a}}\) from a pH Curve
From the titration curve of ethanoic acid with sodium hydroxide, the equivalence point occurs at exactly 24.80 cm³ of NaOH. The pH recorded at exactly 12.40 cm³ of NaOH is 4.76. Calculate the acid dissociation constant (\(K_{\text{a}}\)) of ethanoic acid.

Step 1: Identify the half-equivalence point

\[ \text{Half-equivalence volume} = \frac{\text{Equivalence volume}}{2} = \frac{24.80}{2} = 12.40\text{ cm}^3 \]

Step 2: Relate pH and \(\text{p}K_{\text{a}}\)

At the half-equivalence point, exactly half of the weak acid (HA) has been converted to its conjugate base (A⁻), meaning:

\[ [\text{HA}] = [\text{A}^-] \]

Substituting this equality into the Henderson-Hasselbalch equation:

\[ \text{pH} = \text{p}K_{\text{a}} + \log\left(\frac{[\text{A}^-]}{[\text{HA}]}\right) \implies \text{pH} = \text{p}K_{\text{a}} + \log(1) \implies \text{pH} = \text{p}K_{\text{a}} \]

Therefore, at the half-equivalence point:

\[ \text{p}K_{\text{a}} = \text{pH} = 4.76 \]

Step 3: Convert \(\text{p}K_{\text{a}}\) to \(K_{\text{a}}\)

\[ K_{\text{a}} = 10^{-\text{p}K_{\text{a}}} = 10^{-4.76} = 1.74 \times 10^{-5}\text{ mol dm}^{-3} \]

The acid dissociation constant of the weak acid is 1.74 × 10⁻⁵ mol dm⁻³.

Safety & Risk Assessment

Hazard Risk Precaution
0.10 mol dm⁻³ NaOH Skin irritant; corrosive to eyes. Wear safety goggles and lab coat. Wash splashes off skin immediately.
0.10 mol dm⁻³ ethanoic acid Pungent vapor, skin and eye irritant. Use in a well-ventilated laboratory; wear safety goggles.
Glassware & pH Electrode Breakage can cause cuts. Glass bulb on probe is fragile. Handle electrode carefully. Avoid hitting the probe with the rotating magnetic stirrer bar.

Sources of Error & Improvements

Practise this practical

Exam questions, marked instantly

Write your answer and the AI examiner checks it against the mark scheme, showing exactly which marks you earned and what to add.

Exam-style question

2 marks
[2 marks]

Explain why the vertical section of a weak acid–strong base titration curve is shorter than that of a strong acid–strong base curve.

Show Mark Scheme
  • A weak acid is only partially dissociated, so the pH is higher before the end point (a buffer region forms) [1]
  • So the steep section starts at a higher pH, about 7 rather than about 3, and is shorter [1]

Exam-style question

2 marks
[2 marks]

Explain why no indicator is suitable for a titration between a weak acid and a weak base.

Show Mark Scheme
  • There is no steep (vertical) section at the equivalence point; the pH changes gradually [1]
  • An indicator changes colour over about 2 pH units, so the colour would change gradually over a large volume and there would be no sharp end point [1]
Practical questions appear in your exam papers. Practise them under timed conditions in Exam Mode, with unlimited AI marking and model answers.
See Exam Pass

CPAC Skills Assessed

AQA Examiner Tip

When selecting a suitable indicator, always state that the pH range of the indicator’s colour change must fall completely within the vertical section of the pH curve.

Need to model a titration curve?

Use our interactive Titration Calculator to simulate titration curves, check equivalent points, and verify pH values.

← RP8: Electrochemical Cells (EMF) RP10 (Part 1): Organic Solid Prep →